XH-W3001 220V AC Digital Thermostat
XH-W3001 220V AC Digital Thermostat
Hello; We have compiled all the information about the "XH-W3001 220V AC Digital Thermostat", which is the most commonly used digital thermostat and is also used as a temperature control circuit. We wish you enjoyable reading.
XH-W3001 220V AC Digital Thermostat
XH-W3001 AC 220V 1500W is a digital thermostat with relay output. It is a high precision temperature measurement and control device. It offers a high temperature control accuracy of 0.1 ℃. The temperature control range is between -50 ℃ and 110 ℃. It includes a 1M probe made of waterproof and non-rusting stainless steel material.
XH-W3001 Device Usage and Adjustment:
The device has 1 indicator. This display shows the ambient temperature. There are 2 buttons on the device. The device's settings are made with these buttons.
The device has 1 display. The ambient temperature is shown on this display. There are 2 buttons on the device. The device's settings are made with these buttons.
If the temperature setting connected to the left button is large, the device operates in cooler mode. (Left: 30, Right: 20 Cooler mode)
If the temperature setting connected to the right button is large, the device operates in heater mode. (Left: 20, Right: 30 Heater mode)
You can see these temperature values with short key presses. If you press the buttons for a long time, you can change the settings of the relevant value. After a long press, the buttons start to function as up and down. After adjusting the relevant temperature by pressing the up and down buttons, this value is saved when you wait for a while and the device will start working according to this value.
For example, let's set the value connected to the left button to 37 degrees and the value connected to the right button to 38 degrees. In this case, the device will be in ideal settings for incubation. When the ambient temperature drops below 37 degrees, the heater is activated and the environment begins to warm up. When the temperature rises above 38 degrees, the device turns off the heating. In this case, the ambient temperature will fluctuate between 37-38 degrees.
NOTE: After making the relevant settings, turn the device's power off and on. See that the values you set are saved in the device. If you want to reset the device settings, press and hold both buttons at the same time, the device settings will be reset after a while.
NOTE: If the device screen shows FFF or LLL values or there are large jumps in temperature, it means that the device's temperature probe is faulty. When this probe is replaced, the relevant problem will be eliminated.
Device Connection:
Device Introduction:
17.09.2024